Luminous Sine wave UPS
Being one of the leaders in innovation, design sensibility and sales distribution network, we are offering Power Back Up Solutions and Power Back Up System that includes Power Digital Inverters, Online UPS Systems, Line Interactive UPS Systems, Inverter Batteries (Lead Acid and VRLA).
Features & Protection
- Micro controller based design
- Regulated output voltage window during regulated UPS mode
- Can run single PC up to 8hrs. With 24 V 150 AH battery
- Selectable battery option
- Pre-loaded battery management software
- Charges battery double fast
- Regulated battery charging from 120 V to 300 V
- Automatic holiday mode preserves battery charge
- Advanced digital display
- Audio alarms on mains fail, Charger fuse blown, battery low and no load shutdown
- Phase reversal protection
- Overload with auto re-set
- Battery Deep Discharge protection with two times reset options
- Ultra Fast Short Circuit Protection
- Battery reverse polarity protection
- Miniature circuit breaker for overload and short circuit protection in mains mode instead of cartridge fuse
- DC over Voltage protection.
pecifications of SINEWAVE UPS 600/800/1400VA
|
|
|
INPUT | Regulated UPS mode |
Under Voltage | 180 +/- 5 V |
Undervoltage Restoration | 185 +/- 5 V |
Over Voltage | 260 +/- 5 V |
Over Voltage Restoration | 255 +/- 5 V |
Unregulated UPS mode |
Under Voltage | 100 +/- 10 V |
Undervoltage Restoration | 115 +/- 10 V |
Over Voltage | 285 +/- 10 V |
Over Voltage Restoration | 270 +/- 10V |
OUTPUT | Voltage (UPS Mode) | 230 V(Nominal) |
Voltage (Mains Mode) | Same as Input |
Frequency (UPS Mode) | 50Hz.±2% |
Frequency (Mains Mode) | Same as Input (45-55 Hz.) |
Overload | > 110 % |
Transfer Time (typical a.s) | 10ms. |
BATTERY | Type | 12V/120AH-150AH Lead Acid Type |
Number | 1 |
Typical Recharge Time | 10-12 Hrs. |
Protection | Battery Deep Discharge, Reverse Polarity, DC Overvoltage |
LED DISPLAY | UPS ON | Red |
SWITCH ON | White |
Low Battery Pre-Alarm | UPS ON+LOW BATTERY LED BLINKS |
Battery Low | Red |
Mains On | Red |
Smart Charge | Red (Along with Mains On LED) |
Overload | Red |
Short Circuit | OVERLOAD RED LED BLINKING |
No Load Shut Down | Red |
Battery Charged | Mains On LED steady |
MCB Trip | Mains On+Smart charge blinking |
ALARMS | Low Battery Pre-Alarm | Beeps every 1.5 Minutes |
Low Battery Trip | Beeps Continuously for 10 seconds |
Overload | Beeps Continuously for 10 seconds |
Mains to UPS | Beeps every 2 seconds for 5 times |
Short Circuit | Beeps Continuously for 10 seconds |
No Load Shut Down | Beeps Continuously for 10 seconds |
MCB Trip | Beeps every 12 minutes |
ENVIRONMENTAL | Operating Temperature | 0-45o C (32-113 o F) |
Storage Temperature | 0-45o C (32-113 o F) |
Humidity | 0-95 % RH non -condensing |
*Due to Continuous Product improvements,specs are subject to change without notice. |
| Specifications of SINEWAVE UPS 1500VA
|
|
|
INPUT | Regulated UPS mode |
Under Voltage | 180 +/- 5 V |
Undervoltage Restoration | 185 +/- 5 V |
Over Voltage | 260 +/- 5 V |
Over Voltage Restoration | 255 +/- 5 V |
Unregulated UPS mode |
Under Voltage | 100 +/- 10 V |
Undervoltage Restoration | 115 +/- 10 V |
Over Voltage | 285 +/- 10 V |
Over Voltage Restoration | 270 +/- 10V |
OUTPUT | Voltage (UPS Mode) | 230 V(Nominal) |
Voltage (Mains Mode) | Same as Input |
Frequency (UPS Mode) | 50Hz.±2% |
Frequency (Mains Mode) | Same as Input (45-55 Hz.) |
Overload | > 110 % |
Transfer Time (typical a.s) | 10ms. |
BATTERY | Type | 12V/120AH-150AH Lead Acid Type |
Number | 1 |
Typical Recharge Time | 10-12 Hrs. |
Protection | Battery Deep Discharge, Reverse Polarity, DC Overvoltage |
DISPLAY | UPS ON | ON |
Low Battery Pre-Alarm | Lo |
Battery Low | Lo |
Mains On | AC |
Smart Charge | CH |
Overload | OL (Steady) |
Short Circuit | OL (Blinking) |
No Load Shut Down | Red |
Battery Charged | 99% |
Over Temperautre | th |
MCB Trip | bt |
ALARMS | Low Battery Pre-Alarm | Beeps every 10 seconds |
Low Battery Trip | Beeps Continuously for 10 seconds |
Overload | Beeps Continuously for 10 seconds |
Mains to UPS | Beeps every 2 seconds for 5 times |
Short Circuit | Beeps Continuously for 10 seconds |
No Load Shut Down | Beeps Continuously for 10 seconds |
MCB Trip | Beeps every 12 minutes |
ENVIRONMENTAL | Operating Temperature | 0-45o C (32-113 o F) |
Storage Temperature | 0-45o C (32-113 o F) |
Humidity | 0-95 % RH non -condensing |
Cruze Range
- Adaptive Battery Charging Control (ABCC) technology to avoid the overcharging of the battery
- Pure Sine Wave Output with low THD in output voltage, reducing the noise and helping in smooth operation of device at output
- SMT Based Design for product reliability
- LED Display for describing the product Status
- Miniature Circuit Breaker (MCB) in order to provide the short circuit at output in mains mode
- Electronic Protection against short circuit at output in UPS mode
- “0 Sec” Changeover time from inverter to Mains mode (synchronized changeover)
- Automatic holiday mode preserves battery charge
- Thermal Protection for safety against high internal product temperature
- Very high Load Cold start
- Reverse Battery polarity protection
- Reverse Phase Protection
- No load shutdown feature to protect deep discharge of battery, hence, increasing battery life
- Intelligent battery low cutoff which adjust the battery low cutoff automatically according to load to maintain the longer battery life
- Battery reverse polarity protection
- Miniature circuit breaker for overload and short circuit protection in mains mode instead of cartridge fuse
- DC over Voltage protection.